Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1). Control Box

CONTROL BOX INSTALLATION
1. Decide the installation position of control box first, it is suggested to be installed near the gate and should
be protected from possible damage. Be aware of the motor cable length before deciding the installation position.
2. Remove the cover by unscrewing the four screws on the cover. See Figure 1(1).
3. Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure 1(2).
4. Secure it on the wall. See Figure 1(3).
! CAUTION: There is control board inside, punch with care, do not damage the board
Figure 1(1)
5. Wiring Connection:
Prepare all the wires of the accessories beforehand and connect the wires to the gear motors and accessories on
the PCB as shown in Figure 1(4). All of the wiring connections of the accessories are not requested to
distinguish the positive (+) and the negative (-) polarity.
1). PF-1 Flashing light: Connect the two wires from the flashing light to the terminal LIT (+) and LIT (-) on the PCB.
2). PEL-1 Electric Latch: Connect the two wires from the electric latch to the terminal LAT (+) and LAT (-) on the PCB.
3). Gate openers: Refer to Figure 1(4) and connect the wires separately to the terminals on the PCB.
M1: Connect the motor wire (White +) to the terminals M1 (+), and (Yellow -) to the M1 (-).
Connect the hall sensor wires red, green, and black to the terminals 5V, S1, and GND.
M2: Connect the motor wire (White +) to the terminals M2 (+), and (Yellow -) to the M2 (-).
Connect the hall sensor wires red, green, and black to the terminals 5V, S2, and GND.
Notes:
For gates opened outward,
M1: Connect the motor wire (Yellow -) to the terminals M1 (+), and (White +) to the terminals M1 (-).
M2: Connect the motor wire (Yellow -) to the terminals M2 (+), and (White +) to the terminals M2 (-).
4). PH-1 Photocells: See Figure 1(4)
(A). In the installation of one set: Connect the wires referred to 7 and 9.
And remove the electric jumper "JP1".
(B). In the installation of two sets: connect the wires referred to 7, 8, 9 and 10.
And remove both the electric jumper "JP2"and"JP1". Figure 1(4)
1
Figure 1(2)
Figure 1(3)

Publicité

Table des Matières
loading

Table des Matières