Criteria For The Installation Location; Installing The Appliance; Preparing The Appliance For The First Time - Blaupunkt 5CK2 Série Manuel D'utilisation

Masquer les pouces Voir aussi pour 5CK2 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Equipment and accessories
¡
Installation material
¡
Installation instructions
¡
User manual
¡
Customer service directory
¡
Warranty enclosure
¡
Energy label
¡
Information on energy consump-
¡
tion and noises
4.2 Criteria for the installation
location
WARNING
Risk of explosion!
If the appliance is in a space that is
too small, a leak in the refrigeration
circuit may result in a flammable mix-
ture of gas and air.
Only install the appliance in a
space with a volume of at least
3
1 m
per 8 g refrigerant. The
volume of refrigerant is indicated
on the rating plate. → Fig. 
The weight of the appliance ex works
may be up to 45 kg depending on
the model.
The subfloor must be sufficiently
stable to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate. → Fig. 
Climate
Permitted room tem-
class
perature
SN
10 °C to 32 °C
N
16 °C to 32 °C
1
Depending on the appliance specifications
2
Not in all countries
1
2
/
1
6
/
1
6
Installation and connection en
Climate
Permitted room tem-
class
perature
ST
16 °C to 38 °C
T
16 °C to 43 °C
The appliance is fully functional within
the permitted room temperature.
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5 °C.
Niche dimensions
Observe the niche dimensions if you
install your appliance in the niche. If
this is not the case, problems may
occur when installing the appliance.
Niche depth
Install the appliance in the recom-
mended niche depth of 560 mm.
If the niche depth is smaller, the en-
ergy consumption increases slightly.
The niche depth must be a minimum
550 mm.
Niche width
An inside niche width of at least
560 mm is required for the appli-
ance.
4.3 Installing the appliance
Install the appliance in accordance
with the enclosed installation in-
structions.
4.4 Preparing the appliance
for the first time
Remove the informative material.
1.
Remove the protective foil and
2.
transit bolts, e.g. remove the ad-
hesive strips and carton.
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5cl2 série5cl240ff0

Table des Matières