Electrical Installation - Wittur servogearless WSG-S3.4 Instructions De Service

Table des Matières

Publicité

Electrical installation

5
Electrical installation
5.1
Important notes
INTORQ | BA 14.0196 | 04/2016
DANGER
There is a risk of injury by electrical shock!
❚ The electrical connections must only be made by skilled personnel!
❚ Only carry out connection work when no voltage is applied (no live parts)! There is a risk of
unintended start-ups or electric shock.
NOTICE
❚ Make sure that the supply voltage corresponds to the data on the nameplate.
❚ Voltages must be adjusted to the local environment!
NOTICE
❚ If an emergency stop is carried out without the required suppressor circuit, the control unit
may be destroyed.
❚ Observe the correct polarity of the suppressor circuit!
NOTICE
❚ To functionally test the individual brake circuits, the power supply must be able to be
switched off individually. For a new over-energizing during switch-on, it is also necessary
to open switches K1/K3.
❚ The protective circuitry contained in the INTORQ switching device BEG-561-
(terminals 3 and 4) is not permitted for use in the lift system. The protective circuitry
must be connected parallel to the brake coil (
NOTICE
❚ Only operate the brake with a holding current reduced to 25 % of P
❚ You can use the INTORQ switching device BEG-561-
36).
!
max
-
for this purpose.
-
35

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Servogearless wsg-s3.5Servogearless wsg-s3.6

Table des Matières