Anleitung_TH_RH_1600_SPK1__ 01.07.13 14:46 Seite 13
5.3. Tool insertion (Fig. 4)
Clean the tool before insertion and apply a thin
n
coating of drill bit grease to the shaft of the tool.
Pull back and hold the locking sleeve (2).
n
Insert the dust-free tool into the tool mounting as
n
far as it will go whilst turning it. The tool will lock
itself.
Check that it is properly secure by pulling the
n
tool.
5.4 Tool removal (Fig. 5)
Pull back and hold the locking sleeve (2) and remove
the tool.
5.5 Dust collection device (Fig. 6)
Slide the dust collection device (a) over the drill bit
before carrying out any hammer drilling vertically
above your head.
6. Starting up
Important.
To prevent all danger, the machine must only be
held using the two handles (6/8). Otherwise there
may be a risk of suffering an electric shock if you drill
into cables.
6.1 Switching on and off (Fig. 1)
To switch on:
Press the control switch (4).
To switch off:
Release the control switch (4).
6.2 Hammer stop facility (Fig. 7)
The hammer drill has a hammer stop facility for
gentle initial drilling.
Turn the rotary switch for the hammer stop
n
facility (5) to position (B) to switch off the
hammer facility.
To switch on the hammer facility again the rotary
n
switch for the hammer stop facility (5) must be
turned back to position (A).
6.3 Rotation stop facility (Fig. 8)
For hammer drilling, press the button (E) on the
n
rotary switch (3) and simultaneously turn the
rotary switch (3) to position A.
For chiseling, press the button (E) on the rotary
n
switch (3) and simultaneously turn the rotary
switch (3) to position B. In switch position A the
chisel is not locked.
For chiseling, press the button (E) on the rotary
n
switch (3) and simultaneously turn the rotary
switch (3) to position C. The chisel is locked in
position C.
Important.
Please note that it is not possible to operate the
hammer drill with the hammer stop and rotation stop
facilities both active at the same time.
Important.
Only low pressure is required for hammer drilling.
Excessive pressure will exert an unnecessary force
on the motor. Check the drill bits at regular intervals.
Sharpen or replace blunt drill bits.
7. Replacing the power cable
If the power cable for this equipment is damaged, it
must be replaced by the manufacturer or its after-
sales service or similarly trained personnel to avoid
danger.
8. Cleaning, maintenance and
ordering of spare parts
Always pull out the mains power plug before starting
any cleaning work.
8.1 Cleaning
Keep all safety devices, air vents and the motor
n
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
We recommend that you clean the device
n
immediately each time you have finished using it.
Clean the equipment regularly with a moist cloth
n
and some soft soap. Do not use cleaning agents
or solvents; these could attack the plastic parts of
the equipment. Ensure that no water can seep
into the device.
8.2 Carbon brushes
In case of excessive sparking, have the carbon
brushes checked only by a qualified electrician.
Important! The carbon brushes should not be rep
laced by anyone but a qualified electrician.
8.3 Maintenance
There are no parts inside the equipment which
require additional maintenance.