IKRA IEBV 2600 E Manuel D'utilisation page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Important
Do not use the Vacuum-Blower to suck up water
or very wet debris.
Never operate the Vacuum-Blower without the
debris collection bag fitted.
Blower mode (Fig. 13)
Inspect the area to be worked before starting. Remove
any objects or debris that could be thrown, jammed or
become entangled in the Vacuum-Blower.
Select the blow function using the selector lever on the
side of the machine and switch on. With the Vacuum-
Blower resting on its wheels move the Vacuum-Blower
forwards directing the nozzle at the debris to be cleared.
Alternatively hold nozzle just above the ground and
swing the machine from side to side, moving forwards
and directing the nozzle at the debris to be cleared. Blow
the debris into a convenient heap then use the vacuum
function to collect the debris.
Vacuum mode (Fig. 14)
Inspect the area to be worked before starting. Remove
any objects or debris that could be thrown, jammed or
become entangled in the Vacuum-Blower.
Select the vacuum function using the selector lever on
the side of the machine and switch on. With the Vacuum-
Blower resting on its wheels move the Vacuum-Blower
forwards directing the nozzle at the debris to be col-
lected. Alternatively with the Vacuum-Blower held just
above the ground swing the machine from side to side,
moving forwards and directing the nozzle at the debris to
be collected. Do not force the nozzle into the debris as
this will block the suction tube and reduce the efficiency
of the machine.
Organic materials such as leaves contain a large amount
of water that can cause them to stick to the inside of the
suction tube. To reduce sticking the material should be
left for a few days to dry out.
Cleaning and Storage
Make sure that all nuts, bolts and screws are tight and
that the guards are fitted correctly.
All damaged and worn parts should be replaced in
order to maintain the Vacuum-Blower in a safe working
condition.
Never leave material in the Vacuum-Blower or the debris
collection bag. This could be dangerous when starting
the Vacuum-Blower.
After use the Vacuum-Blower should be thoroughly
cleaned.
Ensure that the Vacuum-Blower is switched off and dis-
connected from the mains supply. Remove and empty
the debris collection bag. Ensure that the Vacuum /
Blow selector lever operates smoothly and that it is not
obstructed by debris. Brush any loose debris from around
the fan and inside the suction/blower tube.
Do not use any type of cleaning solvent on the plastic
parts of the Vacuum-Blower.
GB | Operating Instruction
Power Cord Maintenance
If the supply cord needs replacing, the task must be car-
ried out by the manufacturer, the manufacturer's agent,
or an authorised service centre in order to avoid a safety
hazard.
Troubleshooting
Waste disposal and environmental protection
If your device should become useless somewhere in the
future or you do not need it any longer, do not dispose
of the device together with your domestic refuse, but dis-
pose of it in an environmentally friendly manner. Please
dispose of the device itself at an according collecting/
recycling point. By doing so, plastic and metal parts can
be separated and recycled. Information concerning the
disposal of materials and devices are available from your
local administration.
Repair service
Repairs to electric power tools should only be carried
out by specialist electrical personel. In the case of a
claim for guarantee or defects, please contact the place
of purchase.
Warranty
For this tool, the company provides the end user - inde-
pendently from the retailer's obligations resulting from
the purchasing contract - with the following warranties:
The warranty period is 24 months beginning from the
hand-over of the device which has to be proved by the
GB-6
Attention! Always remove the plug from the
mains socket before starting any work on the
machine.
The machine won't start: Check whether the switch
is in the "ON" position; check that the residual current
circuit breaker is not switched off and that no fuses
have blown in its electric circuit. If the machine still
won't start have it inspected by an authorised cus-
tomer service firm.
The machine won't vacuum: Check whether the
leaf collection bag is full. If it is, empty it; check
whether the lever for the reversing flap is in the cor-
rect position, otherwise have the machine inspected
by an authorised customer service firm.
The machine won't blow: Check whether the lever
for the reversing flap is in the correct position, other-
wise have the machine inspected by an authorised
customer service firm.
The shredder wheel is blocked: Check whether an
object has been sucked in that is too large; a piece of
wood, cardboard or other object has become jammed
between the impeller and shredder chamber. If the
shredder wheel remains blocked have the machine
inspected by an authorised customer service firm.
If the machine vibrates, please immediately stop us-
ing it. Have the machine inspected by an authorised
customer service firm.

Publicité

Table des Matières
loading

Table des Matières