schmalz SCTMi Notice D'utilisation page 41

Table des Matières

Publicité

Default value
-
Unit
0.1 Nl
EEPROM
no
Valeur de fuite des éjecteurs
Parameter
160 (0x00A0)
Description
Leakage rate for ejectors
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint16
Length
32 Byte
Access
read only
Value range
0 ... 8000
Default value
-
Unit
mbar/s
EEPROM
no
Pression d'accumulation des éjecteurs
Parameter
161 (0x00A1)
Description
Free-flow vacuum for ejectors
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint16
Length
32 Byte
Access
read only
Value range
0 ... 999
Default value
-
Unit
mbar
EEPROM
no
Vide maximal des éjecteurs
Parameter
164 (0x00A4)
Description
Max. reached vacuum in cycle for ejector
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint16
Length
32 Byte
Access
read only
Value range
0 ... 999
Default value
-
Unit
mbar
EEPROM
no