schmalz SCTMi Notice D'utilisation page 39

Table des Matières

Publicité

Value range
0x00 = control is not active, H1 in hysteresis mode
0x01 = control is not active, H1 in comparator mode
0x02 = control is active
0x03 = control is active with supervision of leakage
0x04 = control is active, continuous succing disabled
0x05 = control is active with supervision of leakage, continuous succing disa-
bled
Default value
0x02 = control is active
Unit
-
EEPROM
yes
Mode de soufflage des éjecteurs
Parameter
110 (0x006E)
Description
Blow-mode for ejectors
Index
Index 0...15 corresponds to ejector #1...#16
Datatyp
uint8
Length
16 Byte
Access
read/write
Value range
0x00 = externally controlled blow-off
0x01 = internally controlled blow-off – time-dependent
0x02 = externally controlled blow-off – time-dependent
Default value
0
Unit
-
EEPROM
yes
Pression d'alimentation du capteur
Parameter
66 (0x0042)
Description
Primary supply voltage
Index
0: actual value as measured by the device
1: min. value since last power-up
2: max. value since last power-up
Datatyp
uint16
Length
6 Byte
Access
read only
Value range
-
Default value
-
Unit
0.1 V
EEPROM
no
Tension d'alimentation actionneur
Parameter
67 (0x0043)
Description
Auxiliary supply voltage
Index
0: actual value as measured by the device
1: min. value since last power-up
FR · 30.30.01.01598 · 02 · 01/19
Interfaces
39 / 76