Télécharger Imprimer la page

Ecoflam MAX GAS 350 LN P TC SGT 230-50 TW Mode D'emploi page 7

Masquer les pouces Voir aussi pour MAX GAS 350 LN P TC SGT 230-50 TW:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Contents
- Burner description
MAX GAS 350 LN P TC SGT 230-50 TW
RANGE NAME BY FUEL TYPE
MAX GAS Gas
MODEL SIZE (Gas: kW; Oil: kg/h)
MAX GAS 350 350 kW
EMISSION COMBUSTION TYPE
LN
Low NOx Class 3 GAS EN676 (<80 mg/kWh)
-
Standard Class 2-GAS EN676 (<120 mg/kWh)
OPERATION TYPE
P
1 stage
PAB
2 stages
HEAD TYPE
TC
Short head
TL
Long head
FUEL
Natural gas
LPG
LPG
EQUIPMENT
SGT
Separate gas train
ELECTRICAL SUPPLY TO THE SYSTEM
230-50
230 Volt, 50 Hz
CONTROL BOX
TW
Thermowatt
Scope of delivery
The burner is delivered in a modular system of
packagings i.e. separate set/box:
BBCH: Burner Body with Combustion Head
with flange.
- 1 bag including : - multilanguage technical manual.
- wieland plug.
- spanner.
- screws, nuts and washer.
GT: separate Gas Train
KIT & ACS are managed and delivered separately
A1
14
5
420010492303
8
15
F6 M1
A1
E-BCU Gas control unit
F6
Air pressure switch
M1
Electric motor
T1
Ignition transformer
3
Air regulation in the burner head
5
Housing
8
Blast tube
14
Burner hood
15
Burner flange
113
Air intake
KIT & ACS delivered separately
3
www.ecoflam-burners.com
EN
113
7

Publicité

loading

Ce manuel est également adapté pour:

Max gas 350 ln p tl sgt 230-50 twMax gas 500 ln p tc sgt 230-400-50 twMax gas 500 ln p tl sgt 230-400-50 tw314328331432843143285 ... Afficher tout