5. Adjustment of chimney connection.

On delivery, the stove has been prepared for a top outlet but may be amended to use a rear outlet as follows:
Use a hammer and/or screwdriver to remove the plug in the back plate

Positioning of feet

1. Open the combustion chamber door
2. Adjust the feet using a 4-mm Allen key

7. Firing instructions

It is crucial to ensure optimal up-draft in the chimney, at least 12 Pa.. It is essential that the chimney and the wood-burning
stove work together. In essence, the up-draft is affected by the length and area of the chimney but also its pressure
tightness. The least recommended chimney length is 3.5m and the most suitable cross-sectional area i 150-200cm² (140-
160mm in diameter). Your dealer or chimney sweep will be able to assist you with all chimney issues. If you have not used
your chimney for a long time, it should be checked for blockages before use. In some cases, it will be relevant to install a
damper device to control the up-draft in the stove.
Loosen the 2 bolts securing the rear outlet plug
Loosen the 2 bolts securing the flue collar
Switch the flue collar and the rear outlet plug
Insert the top outlet cast iron plug.