Télécharger Imprimer la page

Kemper MINI-TRESOR Instructions D'installation Et D'utilisation page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
1
1.
Align the surface-mounted wall cabinet on the outer wall, and mark and
drill the four holes (Ø 8 mm) and the hole for the frost-free outer fitting
(Ø 27 mm).
2.
Attach the cabinet (1) to the outer wall using the four spacers and
attachment screws (2).
Danger! Earthing!
Connect the earthing with the intended screws at the upper part
of the wall cabinet and the door (All metallic parts are earthed by
this). Metallic parts of the building, to which the wall cabinet
belongs, have to be earthed.
The cross section of the wire is half the cross section of the main
earth wire of the building, or at least 6 mm².
Installation of surface-
mounted wall cabinet
Provide the power supply
- Note FI fuse:
Nominal fault current ≤ 0.03 A,
connection current ≤ 16 A and
connection voltage 230 V
- Protection type IP 44
Info! Following figures
are delivered with
protection type IP 55:
ausgeliefert:
21302015CH
21303015CH
21304015CH
2
Installation of socket combination
1.
Screw the 230 V socket (5) onto the mounting plate (6), connect in the
surface-mounted wall cabinet (1) and attach to the cabinet rear wall
using the screws supplied (7).
Note!
Carry out a functional test!
Danger!
Electrical work must be carried out only by authorised
specialist personnel!
© www.kemper-olpe.de – 11.2021 / K410021300001-00 – 8 /24