Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9. ERROR CODES

Error
LED
code
Press transmitter, but no gate
E0
movement
Gate do not close, but can
E1
Gate can close when it is at
E2
open limit, but cannot open
when it's at close limit.
Press transmitter, but no gate
E3
Press transmitter, but no gate
E4
Press transmitter, but no gate
E5
Press transmitter, but no gate
E7
Press transmitter, but no gate
E8
Press transmitter, but no gate
E9
Motor 1 stop and reverse
F1
during open or close.
Motor 2 stop and reverse
F2
during open or close.
Motor 1 stop and reverse
F3
during open or close.
Motor 2 stop and reverse
F4
during open or close.
Press transmitter, but motor
F5
has no action.
F6
Gate reverse during closing.
Press transmitter, but no gate
F7
Press transmitter or push
F9
button, but motor has no
LE
Motor stops suddenly.
Issue
AP is set to 00
1) IR1 is not connected, or wire is cut.
2) IR1 wire is shorted out or reverse connected.
open.
3) IR1 is not aligned or blocked for a moment.
1) IR2 is not connected, or wire is cut.
2) IR2 wire is shorted out or reverse connected.
3) IR2 is not aligned or blocked for a moment.
1) IR3 is not connected, or wire is cut.
2) IR3 wire is shorted out or reverse connected.
movement.
3) IR3 is not aligned or blocked for a moment.
1) Safety edge is not connected with 8.2kohm
resistor.
movement.
2) Safety edge wire is shorted out.
3) Safety edge is pressed.
1) STOP swtich is open.
movement.
2) STOP switch is not connected.
Control board amplifier for Motor 1 fail.
movement.
Control board amplifier for Motor 2 fail.
movement.
Control board memory mistake.
movement.
Motor 1 is blocked.
Motor 2 is blocked.
Motor 1 stall or speed sensor is damaged.
Motor 2 stall or speed sensor is damaged.
Radio module fail.
Low battery power.
Control board damaged.
movement.
AP menu is reset to factory default.
action.
Press C button during limit learning.
Possible reason
19
Solution
Check if AP is set to 00. If yes, change to correct application setting.
1) Check if IR1 is not connected, or wire is cut.
2) Check IR1 connection, change wires if needed.
3) Align IR transmitter and receiver to make sure both LED is on,
instead of blinking. Make sure there is nothing hanging on gate that
may cause IR blocking.
1) Check if IR2 is not connected, or wire is cut.
2) Check IR2 connection, change wires if needed.
3) Align IR transmitter and receiver to make sure both LED is on,
instead of blinking. Make sure there is nothing blocking the IR.
1) Check if IR3 is not connected, or wire is cut.
2) Check IR3 connection, change wires if needed.
3) Align IR transmitter and receiver to make sure both LED is on,
instead of blinking. Make sure there is nothing hanging on gate that
may cause IR blocking in short time.
1) Check if the 8.2 kOhm safety edge is properly connected or if the
8.2 kOhm resistor is installed.
2) Check safety edge wires and replace wire if needed.
3) Check if safety edge is pressed.
1) Check if STOP switch is open or damaged.
2) Check if STOP switch is disconnected. If yes, then reconnect
STOP switch or change the respective Input setting to other value.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change Control board.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
Check and remove obstruction. Clean gate.
Check and remove obstruction. Clean gate.
Check if motor 1 stalled or speed sensor is damaged.
Check if motor 2 stalled or speed sensor is damaged.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
Charge battery.
Switch off power for 20 seconds and reset to check if control board
recovers. If not, change control board.
Relearn limits.
Relearn limits.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

La300evk

Table des Matières