7. PROGRAMMING

7.3 Wing Movement Direction

Before programming, move the gate manually in the middle position and re-engage
release mechanism (see page 8).
Press and hold the "–" button on the control board and ensure that the motors are
moving in CLOSE direction. If correct, immediately let go of the "-" button and gate
stops.
If motors are moving in OPEN direction, go to the functions "d1" and "d2" and
change the direction settings.
Once CLOSE direction is set correctly, leave the gate in the middle position. The
operator is ready for the Learning phase.
Note: gate can be moved with „ + " and „ - „ buttons prior to final settings if required.
Press and hold the "+" button on the control board to move the gate into OPEN
position. When button is released operator stops.
Press and hold the "–" button on the control board to move the gate into CLOSE
position. When button is released operator stops.

7.4 Basic Settings

Basic Settings Overview
LED
AP
Application
d1
Direction Motor 1
d2
Direction Motor 2
LL
Limit Learning Phase

7.4.1 Application Settings

Application function shown on display.
This function is already pre-set at factory at value 07.
Swing gate, two motors for LA250/LA300 application (defauft)
More settings available on demand:
No application selected
Swing gate, one motor for LA250/LA300 application
Values 01-05 are not suitable for LA250/LA300 application and shall not be chosen.

7.4.2 Direction Motor 1 Settings

Direction Motor 1 function shown on display
Defines movement direction of the Motor 1.
Motor 1 is moving in closing direction
Motor 1 is moving in opening direction

7.4.3 Direction Motor 2 Settings

Direction Motor 2 function shown on display. Defines movement direction
of the Motor 2. Not available for "one motor" application.
Motor 2 is moving in closing direction
Motor 2 is moving in opening direction
Function
Basic Settings (mandatory)
S

7.4.4 Limit Learning

Before starting a Learning phase ensure that:
1. Other Basic Settings are completed
2. Internal / external hard stops are installed (for swing gates)
3. First movement will be in CLOSE direction.
Available Learning methods:
Standard Learning Mode (Automatic)
1. Press and hold "+ and –" buttons for 2 seconds.
2. Automatic learning process starts. LL will flash on the display during complete
process.
3. Wing 2 moves in CLOSE direction until the hard stop is reached, and stops.
4. Wing 1 moves in CLOSE direction until the hard stop is reached, and stops for
2 seconds. Then Wing 1 starts in OPEN direction until the hard stop is reached.
5. Wing 2 moves in OPEN direction until hard stop is reached, stops for 2 seconds
and then moves in CLOSE direction until hard stop is reached, and stops.
6. Wing 1 moves in CLOSE direction until hard stop is reached, and stops.
7. Standard Learning phase is finished. LL will appear on display and board will
return in stand-by mode after 3 seconds.
S
P
NOTE: In single motor application, "Wing 2" actions are not used.
Following settings are done during Standard Learning Mode:
1. Travel length from FULL CLOSED to FULL OPEN position.
2. Opening and closing force for each motor.
3. 15% of total travel in both directions is assigned for Soft Stop.
4. Wing delay in opening and closing position is 2 seconds. Shall you need to
change the delay please go to Advanced Settings: Delay Motor 2 (d0) and
Delay Motor 1 (dC).
11
P
+
+
2 sec.
3 sec.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

La300evk

Table des Matières