5 Specifications related to the product
5.1
Technical data Delta UP 70
Characteristic WITA Delta UP 70
H
(m)
6
5
4
3
2
1
0
0
1
Maximum delivery head
Maximum flow
Power consumption P1 (W)
Supply voltage
Acoustic emission pressure level < 40 dB(A)
EEI
Protective rating
Thermal class
Operating temperature
Fluid temperature
Max. system pressure
Permissible media to be pumped Heating water according to
WITA Delta UP 70-XX
2
3
7.0 m
3,900 l/h
4 - 42
1 x 230V 50Hz
≤ 0,15
IP 42
TF 110
0 °C to 40 °C
+5 to 110°C
10 bar (1 MPa)
VDI 2035
Water/glycol mixture 1:1