3.7.1.3 – 110V/230V electrical system
Tecma products with a 110V/230V motor have a plug, which must be connected to the power
supply. Diagrams in section 8.7/8.10
Plug
Black/Brown
Black/Blue
Black/Grey
Black/Red
WARNING: electrical systems must be connected by qualified personnel. To choose the
wire section, consider the length and power consumption. (see section 7.0). Use the
connectors provided with the TECMA sanitary system.
3.7.2

SINGLE AND MULTIPLE SYSTEM - SALT WATER

3.7.2.1 – hydraulic system
The flushing cycle of the TECMA marine toilet uses external water via a sea cock. Diagrams in
section 8.1/8.2.
When the flushing cycle is started, the control panel starts an inlet pump, which pushes the water
by means of a specific system.
WARNING: The inlet pump is not used as a check valve. This way, water can flow even when
the inlet pump is not running
WARNING: If the toilet is below the floating line, install a vent valve on the inlet and
flushing system. Consider the heeling in case of sailing boats.
WARNING: The inlet pump is not available for models with 110 V/230 Vac motors
www.thetfordmarine.com
Manual rev 25.2014
Main power supply (motor and solenoid valve)
transformer/control unit
transformer/control unit
Tank sensor/control unit
transformer/control unit
TECMA SRL – Via Flaminia / Loc Castel delle Formiche/ 05030 Otricoli (TR) / Italy
/