Dismantling the vermiculite to clean
1: The top baffle plate is to
be pushed up into the front.
4: The upper back plate is
then lifted over the tertiary
beam and placed at the
bottom of the combustion
chamber.
6a: Tool - Allen key 4mm
TT23RG/RGS/RGW
the stove and the chimney
2: The top baffle palte is
carefully lifted over the two
vermiculite posts in front of
the stove.
5: The top baffle plate can
now be removed.
7: After cleaning, assemble
the stove starting at Instruc-
tion 6, Instruction 5 etc....
3: Once the top baffle palte
from instruction 2 has been
lifted, the upper vermicu-
lite back plate can be lifted
across the tertiary beam.
6: Loosen the 4 Allen screws
with a 4mm Allen key. See
Photo 6a. The metal baffle
plates 1 and 2 can now be
slightly pushed back and can
then be removed. The stove
is now ready for cleaning.