Alarm
AL_1: Function
Brush Amp.
AL_2: Function
Aspirator Amp.
AL_3: Function
Power failure
AL_4: Function
Overcurrent
 
AL_5:
Function
Overtemperature
AL_14: Handle
AL_15: Traction
Overtemperature
AL_16: Traction
Power failure
AL_17: Traction
Overcurrent
AL_18: Traction
Traction Amp.
AL_20: General
EEprom failure
AL_22: General
Main relay
AL_23: General
Overvoltage
Meaning
Brush amperometric
protection
Aspirator amperometric
protection
Power stage damaged
Overcurrent on brush or
aspirator outputs
Thermal protection on
brush/aspirator stage
Starting procedure failure
Thermal protection on
traction stage
Traction power stage
damaged
Overcurrent on traction
output
Traction amperometric
protection
Inner memory card error
Main relay damaged
Overvoltage
EN-14
Solution
Check the brush operat-
ing mode. High brush motor
working current detected.
Check aspirator motor ab-
sorption. High aspirator mo-
tor working current detected.
Damaged aspirator or brush
power stage: replace card.
Short circuit detected on
brush or aspirator motor out-
put: check connections and
motor state.
Brush and aspirator power
stage overheating: check ab-
sorption.
Do not touch the touch sen-
sor (20) while pressing the
ON/OFF button.
Traction power stage over-
heating: check absorption.
Damaged
traction
stage: replace card.
Short circuit detected on
traction motor output: check
connections and motor state.
Check the traction operating
mode. High traction motor
working current detected.
Replace card.
The main relay on the card
appears damaged: replace
the card.
Overvoltage on function card
detected.
Check the battery connec-
tions.