Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 75
Description
Required minimum volume flow
Maximum flow rate (6 bar, air regu-
lator open wide)
Operating temperature
Storage temperature
Max. tube length
Noise level (2.5 bar, air regulator
completely closed)
Noise level (6 bar, air regulator
completely open)
Weight
Operating pressure of compressed
air safety tube

8. First Use

The air regulator is delivered in an assembled and operationally ready
state.
Check after unpacking:
■ Air regulator damaged.
■ Scope of supply complete (see chapter 5).
8.1. Personalise air regulator.
The air regulator can be personalised with a CCS disk [3-1]. The air regu-
lator is supplied ex works fitted with a red CCS disk [3-2].
■ Pull off the CCS-disk on the air regulator and replace it with a CCS-disk
of a different colour.
8.2. Exchange fastening module on carrying side.
Notice!
The air regulator is supplied ex works with the fastening module fitted to 
the air regulator for right-handed operation.
The breathing protection hood connection must always point to the rear.
■ Fold the hood holder [4-3] down.
■ Unscrew the screws [4-2].
■ Change the side for fitting the hood holder and fastening module [4-1].
■ Fasten the hood bracket and the fastening module to the air regulator
Operating instructions SATA air regulator
150 Nl/min
740 Nl/min
5 °C – 60 °C
-20 °C – 60 °C
approx. 300 g
max. 10,0 bar
5,3 cfm
26,1 cfm
41 °F – 140 °F
-4 °F – 140 °F
40 m
64 dB (A)
79 dB (A)
approx. 10,6
max. 145 psi
EN
Unit
oz.
55