Télécharger Imprimer la page

F.Bertazzoni PM36500X Mode D'emploi page 6

Publicité

Les langues disponibles

Les langues disponibles

Lift up the burners and unscrew the nozzles ( Fig. 9) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE N°2: Adapting to different types of gas
Burner
Type of Gas
Semi-
Natural G20
Rapid
Butane G30
Propane G31
Natural G20
Rapid
Butane G30
Propane G31
Dual
Natural G20
burner
Butane G30
inner
Propane G31
Dual
Natural G20
burner
Butane G30
outer
Propane G31
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Regulation of the "MINIMUM" on the burners
To regulate the minimum on the burners carry out the following procedure indicated below:
1) Turn on the burner and put the knob onto position MINIMUM ( small flame ).
2) Remove the knob ( Fig. 10) of the tap which is set for standard pressure. The knob is found on the bar of
the tap itself.
3) Beside the tap bar on the work top, use a small screwdriver that fits the screw (gold) found on the lower
part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most
suitable way to MINIMUM.
4) Make sure that that the flame does not go out when changing the position quickly from MAXIMUM to the
MINIMUM position.
ATTENTION: The regulation described above can be carried out only with burners using natural gas,
while with burners using propane gas the screw must be fully screwed in, in a clockwise direction.
Descriptions
DESCRIPTIVE CAPTION FOR HOB
1. Dual burner
2. Rapid burner
3. Medium burner
4. Dual in burner control knob
5. Dual out burner control knob
6. Medium burner control knob
7. Rapid burner control knob
Service & maintenance instructions
Service and maintenance only to be carried out by an authorised person
To replace parts such as burners, valves and electric components, the hotplate must be removed from the
bench top by releasing the attachment hooks, loosening the attachment screws of each burner, unscrewing
Pressure
Nozzle
diameter
mbar
1/100mm
g/h
20
101
28
66
127
37
66
125
20
129
28
87
218
37
87
214
20
70
28
46
211
37
46
207
20
2x110
28
2x69
298
37
2x69
293
APPLIANCE CATEGORY: II2H3+
Nominal Charge
l/h
Kw
kcal/h
-
167
1,75
1505
-
1,75
1505
-
1,75
1505
-
286
3
2580
-
3
2580
-
3
2580
-
76
0,8
-
0,8
-
0,8
-
419
4,4
3784
-
4,1
3526
-
4,1
3526
DESCRIPTION OF HOBS
Model 'A' Fig. 11
Model 'B' Fig. 12
Reduced Charge
kw
kcal/h
0,44
378
0,44
378
0,44
378
0,75
645
0,75
645
0,75
645
688
0,30
258
688
0,30
258
688
0,30
258
1.8
1548
1.8
1548
1.8
1548
Diameter
by-pass 1/100mm
31 reg
31
31
42 reg
42
42
27 reg
27
27
65 reg
65
65

Publicité

loading

Ce manuel est également adapté pour:

Pm365s0x