INSTALLATIoN
Installation

10.4 Appliance installation

1 Wall mounting bracket
f Hook the appliance onto the bottom tabs of the wall mount-
ing bracket by the slots in the back of the appliance.
f Place the appliance in an upright position.
f Secure the appliance by pushing it towards the wall until it
audibly snaps into place in the two upper springs on the wall
mounting bracket.
1
1 Appliance
2 Locking screw
f Secure the appliance against unintentional release using
the supplied locking screw on the left-hand side of the wall
mounting bracket.

10.5 Removing the appliance

f Undo and remove the locking screw from the wall mounting
bracket.
f To release the appliance, push down the springs at the top of
the wall mounting bracket.
f Tilt the appliance away from the wall and lift it off the bottom
tabs on the wall mounting bracket.
24
| CNS Trend | CNS Trend U

10.6 Electrical connection

1
Only an authorised electrician is allowed to make the permanent
connection to a junction box.
2
10.6.1 CNS Trend series
The appliance is delivered fully wired. The following electrical
connections are permissible:
Connection to a freely accessible standard socket
with matching plug
Permanent connection to an appliance junction box
with earth conductor
- If connecting the appliance via a socket, ensure that this is
easily accessible once the appliance has been installed.
- If connecting the appliance permanently, trim the power
cable so that it leads directly to the appliance connection
socket. Ensure that, after trimming the power cable, the
appliance can still be removed from the wall without a
problem.
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with national and regional regulations.
WARNING Electrocution
- In the case of a permanent connection, the appli-
ance must be able to be separated from the power
supply by an isolator that disconnects all poles with
at least 3 mm contact separation.
- Do not install the appliance with a fixed power
cable.
Note
- Observe the type plate. The specified voltage must
match the mains voltage.
- Ensure the on-site supply cable has an adequate
cross-section.
Note
In a non-domestic environment and in case of particu-
larly high demands on the appliance, such as permanent
continuous operation, we recommend installing the ap-
pliance as a permanent connection with a junction box.
WARNING Electrocution
- Provide appropriate strain relief when making the
connection to a junction box.
- Ensure that the appliance is connected to the earth
conductor.
- Seal the trimmed cable ends again correctly with
wire ferrules.
www.stiebel-eltron.com