O 5001 / OXI1408T
the device.
CAUTION: Don't use strong solvent. For example, acetone.
CAUTION: Never use an abrasive such as steel wool or metal polish.
CAUTION: Do not allow any liquid into the product, and do not immerse any parts of the
device into any liquids.
CAUTION: Avoid pouring liquids on the device while cleaning.
CAUTION: Don't remain any cleaning solution on the surface of the device.
*Replace the batteries timely when battery indication is low.Clean surface of the Pulse
Oximeter before it is used in diagnosis for patients.
*Remove the batteries inside the battery cassette if the Oximeter will not be operated for a
long time.
*It is better to preserve the product in a place where ambient temperature is -10-40 ℃ and
humidity is 10%-80%.
*Regular inspection to make sure that no obvious damage existed to affect the safety and
performance of device.
*No flammable substance, overtop or lower temperature and humidity existed in operation
conditions.
D.
TROUBLESHOOTING
Table 5.2.1 troubleshooting
*Problems:Oxyhemoglobin or heart rate can not be shown normally
*Possible Reason:Finger is not plugged correctly.2.Patient's perfusion is too low to be measured.
*Resolutions:Retry by plugging the finger2.Try some more times, If you can make sure
about no problem existing in the product, Please go to a hospital timely for exact diagnosis
*Problems:Oxyhemoglobin of heart rate is shown unstably
Possible Reason:
1. Finger might not be plugged deep enough.
2. Finger is trembling or patient's body is in movement status
Resolutions:
1.Retry by plugging the finger
2.Try not to move, Let the patient keep calm.
*Problems:The Oximeter can not be powered on
*Possible Reason:1. Power of batteries might be inadequate or not be there at all
2.Batteries might be installed incorrectly 3.The Oximeter might be damaged
*Resolutions:1. Please replace batteries 2.Please reinstall the batteries 3.Please contact
with local customer service center.
*Problems:The screen are suddenly off
*Possible Reason:1 The product is automatically powered off when no signal is detected
longer than 8 seconds2.Power quantity of the batteries is exhausted.
*Resolutions:1. Normal2. Replace the batteries.
E.
FEATURES
*Lightweight for carrying and Easy-To-Use.
*Manually adjust the direction of interface .
*Color OLED display, simultaneous display for testing value and
plethysmogram.
*Low Perfusion down to 0.3%.
*Visual alarm function. Real-time spot-checks.
*Low Battery voltage indicator.
*Automatically switch off.
*Standard two AAA 1.5V Alkaline Bаttеrу support more than 20 hours
continuous work.
The European directive 2012/19/EC about electronic and electric waste, requires that you can't
throw away defective domestic appliance with common waste. Used device has to be collect separately
to optimize the recuperation rate and the recycling of the materials to reduce the impact on the health
and the environment.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capacities, or by persons lacking in experience or knowledge, unless they are supervised or
instructed on the use of this apparatus by a person responsible for their safety.Children should be
supervised to ensure they do not play with this appliance.
Precision and precautions about the battery use
o
Throwing away a used battery in the environment or with household waste pollutes and
avoids the recuperation of reusable materials.
o
It is important to limit the battery consumption and to respect the following rules:
Favor alkaline battery (last longer than saline battery) and when it's possible use
rechargeable battery.
Leave used batteries and accumulators in adapted containers that you can find in some
retailers. In that way, metals don't pollute the environment and the health.
o
Battery has to be inserted by respecting the polarity show on the apparel and the battery. An
incorrect positioning can damage the apparel, cause leaking and even provoke fire and the explosion of
the battery.
o
To assure a good functioning, battery has to be in a good condition. If there is a problem, put
new battery.
o
Never try to recharge battery not made for this. It could leak, warm up, cause fire or explode.
o
Replace all the battery at the same time. Never mix up alkaline battery with saline battery.
o
Used battery has to be removed.
o
Also, remove the battery if you're not using the apparel for a long time.
o
Never try to short-circuit the terminal of a battery.
o
Never throw away the battery in fire because they can explode.
o
Take out the accumulator from the apparel before reload it.
o
We recommend that an adult watch if a child change the battery to respect those rules.
o
If you swallow a battery, go immediately to your doctor or the hospital.
o
For the best ongoing performance, we recommend using only fresh, high-quality, alkaline
batteries.