To end the minimum/maximum measurement,
briefly press the measuring button 7. Pressing
the measuring button again starts a new meas-
urement.
The minimum/maximum measurement can also
be used for length measurements within other
measuring modes (e.g. area/surface measure-
ment). For this, press button 13 once for mini-
mal measurement and twice for maximal meas-
urement each time when determining individual
measured values. Then press the measuring but-
ton 7 to switch the laser beam on. Move the
measuring tool in such a manner that the de-
sired minimum or maximum value is measured,
and press the measuring button 7 to take over
the minimum or maximum value into the current
calculation.
For time-delayed length measurements and
when in mark-out mode, minimum/maximum
measurements are not possible.
The minimum/maximum measurement automat-
ically switches off after 5 min.
Area Measurement
For area/surface measurements, press button 4
until the indicator for area measurement
pears on the display.
Afterwards, measure the length and the width,
one after another, in the same manner as a
length measurement. The laser beam remains
switched on between both measurements.
Upon completion of the sec-
ond measurement, the sur-
face is automatically calculat-
ed and displayed in the result
line c. The individual meas-
ured values are displayed in
the measured-value lines a.
Bosch Power Tools
Volume Measurement
For volume measurements, press button 4 until
the indicator for volume measurement
pears on the display.
Afterwards, measure the length, width and the
height, one after another, in the same manner as
for a length measurement. The laser beam re-
mains switched on between all three measure-
ments.
Upon completion of the third
measurement, the volume is
automatically calculated and
displayed in the result line c.
The individual measured val-
ues are displayed in the
measured-value lines a.
Values above 999999 m
cated; "ERROR" and "––––" appear on the dis-
play. Divide the volume to be measured into in-
dividual measurements; their values can then be
calculated separately and then summarized.
Indirect Length Measurement
(see figures H–K)
The indirect length measurement is used to
ap-
measure distances that cannot be measured di-
rectly because an obstacle would obstruct the
laser beam or no target surface is available as a
reflector. Correct results are achieved only when
the right angles required for the respective meas-
urement are exactly adhered to (Pythagorean
Theorem).
Pay attention that the reference point of the
measurement (e.g. the rear edge of the measur-
ing tool) remains exactly at the same location
for all individual measurements within a measur-
ing sequence (exception: trapezium measure-
ments).
The laser beam remains switched on between
the individual measurements.
For indirect length measurements, four measur-
ing modes are available. Each measuring mode
can be used for determining different distances.
To select the measuring mode, press the func-
tion-mode button 3 until the symbol of the de-
sired measuring mode is indicated on the display.