Countdown Timer:

Slide the mode selector switch on the back of the device to the timer
position
.
The second row of the screen will display the timer information and the
first row of the screen will toggle the display of the temperatures of Probe
EN
1 or 2.
Press ▲/HR to set the hours and ▼/MIN to set the minutes.
Press S/S (start/stop) button to start the countdown timer. The colon
between hours and minutes will flash.
If the setting or the remaining countdown timer is less than 1 hour, the
display will automatically switch to display the minutes and seconds.
When the timer gets to 00:00, the alarm will sound. Press any button to
silence the alarm. The device has a timing memory and will automatically
display the original timer setting when S/S is pressed to silence the
alarm.
To clear the timer setting, press the ▲/HR and ▼/MIN buttons at the
same time. You can pause the timer while it is running by pressing S/S
button. Press S/S button again to restart the timer.
If you are using the timer and thermometer at the same time, you may
slide the selector switch back to the cook position during the timing
session to set or view the cooking temperatures. The timer will continue
the countdown . The alarm will sound when it reaches 00:00 and you can
silence the alarm by pressing any button.

Count up Timer:

Slide the mode selector switch on the back of the device to the timer
position
.
-11-
Press the ▲/HR and ▼/MIN buttons at the same time to clear the timer
setting to 00:00.
Press S/S button to start count up timer. Press it again to stop/re-start
the timer.
The timer will stop when it reaches 99 Hour:59 Minute.
If you are using the timer and thermometer at the same time, you may
slide the selector switch back to the cook position during the timing
session to set or view the cooking temperatures. The timer will continue
counting up .
Note: When setting the timer, you can press and hold ▲or▼ for fast setting.

Cleaning and Care

The device is not waterproof. Do not expose plug of probe or plug-in hole
to any liquid, which will result in a bad connection and faulty readings.
The probe and cable are not dishwasher safe. They must be hand washed
using hot water and soap. Make sure to rinse and dry the probe thoroughly
before storing.
Do not submerge the device in water or expose to any corrosive cleaning
materials. Wipe with damp cloth.

Limited One-Year Warranty

ThermoPro warrants this product to be free of defects in parts, materials
and workmanship for a period of one year, from dateof purchase.
Should any repairs or servicing under this warranty be required, contact
Customer Service by phone or email for instructions onhow to pack and ship
the product to ThermoPro.
-12-
EN

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières