3 Safety
Warning:
Work on the equipment must be carried out by a skilled and qualified electrical engineer
according to the applicable national and local regulations.
The anti-static bar is only designed for neutralising electrostatically charged surfaces.
When working on the equipment, always disconnect the power supply to the equipment.
Make sure that the equipment is properly earthed (see installation).
Earthing is needed to ensure safe and proper operation.
The emitters are sharp and can cause physical injury.
High voltages are hazardous for people who have a pacemaker.
The high-voltage emitters (30 kV) are limited to a current of 150 µA, which means that they are
electrically safe to touch and shockproof.
Coming close or making contact with a emitter from one polarity can have the effect that a
person will become electrostatically charged and gets a shock reaction when the person
discharges to other earthed or uncharged objects (maintain a distance of at least 300 mm from
the bar).
When an overload occurs the high voltage will be regulated down until the max. internal current
level is reached.
The concentration of ozone generated varies per application and must be checked.
If changes or modifications, etc. have been made without prior consent in writing, or if original
parts have not been used for repairs, CE/UL approval for the equipment will be withdrawn
and the equipment will no longer be under guarantee.