INSTALLATION
Securing the operator
1
Door structure
2
Keyed door shaft
3
Cotter pin and locking screw
4
Operator
5
Operator support
6
Operator attachment screws and
washers
7
Support attachment screws or lag
screws
The screws (7) are not supplied.
Use screws which are suitable for
the place of attachment and the
effort of the operator.
O
The cotter pin locking screw (3) should
be tightened to lock the cotter and
prevent sideways movement.
Limit switches adjustment
Closing limit switch (FCC)
1 Close the door manually.
2 Adjust the LC camshaft (white) for the FCC limit
switch to open.
3 Tighten screw A to secure the camshaft. Fine
adjustment is done by turning screw B.
4 Carry out an operation test (having completed the
electrical connections as explained in the following
section), and then check the torque of screw A.
Additional limit switch (FCS)
FCS (contacts normally closed) will be used in accordance with the requirements of each installation or
customer. Adjustment is the same as for FCA and FCC.
20
Installation Guide
Opening limit switch (FCA)
1 Open the door manually.
2 Adjust the LA camshaft (green) for the limit switch
to open (FCA).
3 Tighten screw C to secure the camshaft. Fine
adjustment is done using screw D.
4 Carry out an operation test (having completed the
electrical connections as explained in the following
section), and then check the torque of screw C.
P93C