Télécharger Imprimer la page

Italtecnica Brio2000 Mode D'emploi page 16

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
GB
WARNING: TO ENSURE CORRECT WORKING OF THE BRIO 2000,
MAXIMUM PUMP PRESSURE MUST BE AT LEAST 0,6 BAR HIGHER
THAN BRIO 2000 OPERATING PRESSURE.
5. STARTING BRIO 2000
WARNING: whenever the level of the priming water is lower than the
level of the water where the pump is placed, a suction line equipped
with an antibackflow foot valve is absolutely essential. This valve allows
the line to be filled when it is first used and prevents it from being
emptied when the pump stops.
1.
Before turning on, fill up the suction pipe and pump with water and then
start the pump by connecting the Brio 2000 power plug to a current
outlet; when the pump stops open the tap situated higher up.
2.
Installation is correct if the flow from the tap is regular and if the pump
works continuously. If there is no water you can try to make the pump
work without interruption - for a period of time longer than the device's
working time - by keeping the RESET button depressed. If the problem
persists, disconnect the Brio 2000 and repeat the procedure from point
1.
6. DRY STOP
The red FAILURE LED lits up with motor off to indicate a dry stop. To start the
system again press the RESET button after having checked the presence of
water in the suction pipe.

Publicité

loading

Ce manuel est également adapté pour:

Brio2000-7Brio2000-mBrio2000-mt