6. Engine and capacitor
The following Fig. 13 shows the connection between the capacitor and the control board as well
as the connection between the engine and the control board. The connections have been done in
the gate operator.
V-com
U-Positive direction
W-Opposite direction
PE-Protective grounding
S
etting the autoMatic cloSing tiMe
You can set the sliding door to close automatically after 0, 30, 60 or 90 seconds on "IC3" DIP switch
of the control box.
ON
0 seconds:
Slide the 2nd and 3rd DIP switches to the "on" position (without auto-close function).
1 2 3
ON
30 seconds:
Slide the 2nd DIP switch to the "on" position and the 3rd switch to the "off" position.
1 2 3
ON
60 seconds:
Slide the 2nd DIP switch to the "off" position and the 3rd switch to the "on" position.
1 2 3
ON
90 seconds:
Slide the 2nd and 3rd DIP switches to the "off" position.
1 2 3
DE FR EN ES
EN
Fig. 13
Capacitor
C
Control board
Terminal X3
38
PE
PE
C
V
V
U
U
W
W
Engine
V
V
U
U
W
W
Terminal X2