NOTE: the SAF-HD 7 models provides 7 fi lters.
The fi lters are programmed within the "FILTERS" menu. Each fi lter must be programmed individually by
The
setting the following: input associated with the fi lter, frequency or channel to fi lter, frequency or output
channel, offset and output level.
Entering the "FILTERS" menu, the following will appear:
)
To select the fi lter to be programmed, use the left/right arrows and press
selected fi lter.
From this menu, it will be possible to select the channel to fi lter (by frequency or channel number), as well as
to select the output channel (by frequency or channel number), to set the OFFSET (by steps of 125KHz) and
to set the channel output level.
The selected fi lter fl ashes
NOTES:
All fi lters are OFF by default. To enable them, set the channel output level (by default, it is OFF).
After setting the fi lter level to AUTO, start the AUTOMATIC EQUALIZATION from the EQUALIZATION
menu.
RF EQUALIZE
SETTINGS
Show 10 fi lters in SAF-HD
X: fi lter off (fi lter level is OFF);
if the fi lter is on (fi lter level different from OFF):
1: fi lter associated to the UHF1 input;
2: fi lter associated to the UHF2 input;
3: fi lter associated to the UHF3 input;
Input channel fi ltred *
FILTERS
<1XXXXXXXXX> 01
5.4 EQUALIZATION SETTINGS MENU
RF EQUALIZE
AUTO
RF EQUALIZE
MANUAL
FILTERS
<XXXXXXXXXX> --
Output channel (converted)*
E32 - E21
ATTENTION
V=Start-up
MANUAL
<989A999999> 01
FILTERS
<989A999999> 02
29
to enter the programming of the
* if the fi lter is
enabled
Indication of the number of
fi lters you are programming
Execute the automatic
equalisation of the filtered channels
0
...
9
A
To confirm

Publicité