EuroLite NB-100 ICE Mode D'emploi page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Manual ON/OFF without lock:
To engage the manual function, depress and hold the green MANUAL ON/OFF button. Fog emission will be
at 100%. To quit this function, release the green MANUAL ON/OFF button and fog emission will stop.
Important: Always monitor tank fluid level as you are fogging. Running a fog machine with no fluid can
permanently damage the unit.
If you experience low output, pump noise or no output at all, unplug immediately. Check fluid level, the
external fuse, remote connection, and power from the wall. If all of the above appears to be O.K., plug the
unit in again. If fog does not come out after holding the remote button down for 30 seconds, check the hose
attached to the tank to make sure there is fluid going through the hose. If you are unable to determine the
cause of the problem, do not simply continue pushing the remote buttons, as this may damage the unit.
Return the machine to your dealer.
DMX Control Mode
For DMX Control Mode, at least one dip switch must be set on ON.
DMX-512 connection / connection between fixtures
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
resistor
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
18/38
51701982_V_1_0.DOC

Publicité

Table des Matières
loading

Table des Matières