Key; Warranty; Important Notes; Application - Franke 2000101182 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
2.

Key

Warning!
Failure to observe can result in bodily injury or even death.
Caution!
Failure to observe can result in material damage.
Important!
Failure to observe can cause the product to malfunction.
Useful information for optimum handling of the product.
3.

Warranty

Liability is accepted in accordance with the General Terms and Conditions of
Business and Supply.
Use only genuine spare parts!
4.

Important notes

• Installation, commissioning and maintenance are to be performed only by a
qualified expert in accordance with the provided instructions, legal requirements
and the recognised engineering standards.
• All technical connection regulations specified by the local water and electricity
supply companies must be observed.
• We reserve the right to make changes.
5.

Application

Electronic module A3000 open, for system flushing with cold water (hygiene flush)
and hot water (thermal disinfection) via ECC function controller. Combined for
concealed installation.
6.

Technical specifications

Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculated flow rate:
Volumetric flow:
Operating voltage:
Power consumption:
Communication:
Protection class:
1 bar
1-5 bar
10 bar
0.15 l/s
0.15 l/s
0.30 l/s at a flow pressure of 3 bar
24 V DC
4.5 W
Ethernet via ECC function controller
IP 68