Table Des Matières; Important Safety Instructions - Waterco Electroheat Ultra Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Table of
A NOTE TO YOU -------------------------------------- 03
INSTALLATION INSTRUCTIONS -------------------- 05
Location ------------------------------------------ 05
Installation Clearances -------------------------- 06
Water Piping ------------------------------------- 07
Water Flow Rate --------------------------------- 08
Water By-pass Kit ------------------------------- 08
Plumbing Diagram ------------------------------ 08
Electrical ------------------------------------------ 09
Electrical Connection --------------------------- 09
Breaker Size -------------------------------------- 09
Electrical Wire Size ------------------------------ 09
Bonding ------------------------------------------- 10
Bonding Diagram -------------------------------- 10
Remote Control Connections ------------------ 11
Usage Of Chemical Products ------------------ 12
CONTROLLER TYPES
Initial Heating ------------------------------------ 13
Pool Heat Pump Running Time ---------------- 14
Pool Solar Blanket ------------------------------- 14
Defrost Cycle ------------------------------------- 14
To Start The Pool Heat Pump ------------------ 15
To Stop The Pool Heat Pump ------------------ 15
To Check and Adjust Temperature
Settings ------------------------------------------- 16
Temperature Calibration ------------------------ 17
To Change Display From Farenheit To
Celcius -------------------------------------------- 18
Defrost for Electroheat Ultra ------------------- 18
Protection Devices ------------------------------ 18
Codes --------------------------------------------- 18
Inverter Controller Operation ------------------------ 20
Timer Function ----------------------------------- 20
Function Descriptions -------------------------- 21
Buzzer --------------------------------------------- 21
Memory Function -------------------------------- 21
Cabinet Cleaning -------------------------------------- 22
Cleaning Evaporator ---------------------------------- 22
Cleaning drainage holes ------------------------------ 22
Winterising Procedure -------------------------------- 23
GENERAL SAFETY INSTRUCTIONS ---------------- 24
TROUBLESHOOTING --------------------------------- 25
or a Code --------------------------------------- 25
Are Not Moving) -------------------------------- 25
Functioning ---------------------------------------- 26
Compressor Starts and Stops ----------------- 26
Pump ------------------------------------------------ 26
Evaporator Coil --------------------------------- 27
Not Reach The Desired Temperature
Setting -------------------------------------------- 27
Analysis Chart ------------------------------------ 28
Circuit Breaker Trips ----------------------------- 28
The Pool Heat Pump Is Noisy ------------------ 29
Service Analyser Codes ------------------------- 30
WARRANTY -------------------------------------------- 35

IMPORTANT SAFETY INSTRUCTIONS

When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
! WARNING: Disconnect all AC power during installation and servicing.
! WARNING: In order to avoid the possibility of hyperthermia (heat stress) occurring
it is recommended the average temperature of the spa - pool water does not exceed
40˚C.
! WARNING: The pool heat pump is not intended for use by persons (including
children) with reduced physical sensory or mental capabilities, or lack of experience
and knowledge, unless they have been provided supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be
supervised to ensure they do not play with the appliance.
• In certain situations unexpected start up may occur when the appliance is in
automatic mode.
• The installer should assess the risk associated with unexpected start-up of this
device which, in any circumstance should have no hazardous effect.
• The pool heat pump is not meant to provide safety protection for other devices.
• The pool heat pump should be deactivated if the pool or spa has been drained.
• Waterco pool heat pumps must be installed by a suitably qualified person in
accordance with current Regulatory Standards, the applicable Wiring Rules
(AS3000) and local statutory authority regulations.
• Parts containing live parts, except parts supplied with safety extra-low voltage
not exceeding 12V, must be inaccessible to a person in the spa - pool.
• Parts incorporating electrical components, except remote control devices, must
be located or fixed so that they cannot fall into the spa - pool.
• The appliance should be supplied through a residual current device (RCD) having
a rated residual operating current not exceeding 30mA.
• An Earth terminal is located inside the wiring enclosure. To reduce the risk of
electric shock, this terminal must be connected to the grounding means provided
in the electric supply service panel with a continuous copper wire as sized to
comply with current Standards and local statutory authorities in relation to the
circuit conductors supplying the equipment.
• A cable connector is provided on this unit to connect a suitably sized copper
conductor between this unit and any metal equipment, metal enclosures of
electrical equipment, metal water pipe, or conduit within 1.5m of the unit via
equipotential bonding.
SAVE THESE INSTRUCTIONS.
Pool Heat Pump
I pg 02

Publicité

Chapitres

Table des Matières
loading

Table des Matières