SamplexPower PST-1500-12 Mode D'emploi page 48

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SECTION 11 |
ISSUE
There is no AC output. Green
indication on the GFCI (5d,
Fig 6.1) is OFF. The Green LED
marked "POWER" (2, Fig 6.1)
is lighted. No buzzer alarm.
Red LED indication on the
GFCI (5c, Fig 6.1) is perma-
nently ON or flashing. The
Green LED indication of the
GFCI (5d, Fig 6.1) may be
ON or OFF. The Green LED
marked "POWER" (2, Fig 6.1)
is lighted. No buzzer alarm.
48 | SAMLEX AMERICA INC.
Troubleshooting Guide
POSSIBLE CAUSE
GFCI has tripped due to
leakage or due to Neutral
to Ground bond on the
load side.
Self monitoring test of
GFCI is defective.
REMEDY
Check load side circuits for leakage or Neutral
to Ground bond. Switch ON the inverter if in
OFF condition. Check that Status LED (2, Fig
6.1) is Green. Press Reset Button on the GFCI to
reset the GFCI. On resetting, the Green indica-
tion on the GFCI will switch ON.
The GFCI will be required to be replaced. Call