SamplexPower PST-1500-12 Mode D'emploi page 39

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SECTION 8 |
For Line and Neutral wires: Nylon Insulated, Cord End
Terminals for AWG #12 wire ........................................................................ 2 pieces
For Neutral wire: Non Insulated Ring Terminal for #6 stud ....................... 1 piece
Use proper crimping Tool to crimp the terminals to the bare ends of the wire. Make sure
that the connections are tight and firm. Please ensure that the AC cable is adequately
clamped by the metal Strain Relief Clamp (11). Please use the following type designation of
AC cord: "SE, SEOO, ST, STO, SJ, SJEOO, SJT, or SJTO."
8.6 GROUNDING TO EARTH OR TO OTHER DESIGNATED GROUND
For safety, ground the metal chassis of the inverter to the Earth Ground or to the other
designated ground (For example, in a mobile RV, the metal frame of the RV is normally
designated as the negative DC ground). An equipment grounding Lug (7) has been pro-
vided for grounding the metal chassis of the inverter to the appropriate ground.
When using the inverter in a building, connect a 10 mm
copper wire from the above equipment grounding lug to the Earth Ground connec-
tion ( a connection that connects to the Ground Rod or to the water pipe or to another
connection that is solidly bonded to the Earth Ground ). The connections must be tight
against bare metal. Use star washers to penetrate paint and corrosion.
When using the inverter in a mobile RV, connect a 10 mm
copper wire from the above equipment grounding lug to the appropriate ground bus of
the RV (usually the vehicle chassis or a dedicated DC ground bus). The connections must be
tight against bare metal. Use star washers to penetrate paint and corrosion.
8.7 OPTIONAL WIRED REMOTE CONTROL: MODEL RC-300
An optional Wired Remote Control Model No. RC-300 (with 16.5 ft. / 5 metre cable),
is available for switching ON and switching OFF. It is plugged into Modular Jack (10,
Fig 6.1). The Remote Control has LCD display showing AC output V, A, Hz, W, VA and
Power Factor (PF). It also has LED indications similar to the indications on the front panel
(2,3,4 in Fig. 61). Read Remote Control Manual for details.
i
INFO
For the Remote Control RC-300 to operate, the ON/OFF Switch on the inverter
(1, Fig 6.1) should be in ON condition.
Installation
or AWG #8 insulated stranded
2
or AWG #8 insulated stranded
2
SAMLEX AMERICA INC. | 39

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Pst-1500-24Pst-2000-12Pst-2000-24

Table des Matières