Trouble shooting
Problem
Cause
Unit does not produce.
Mixing head is
clogged.
Cleaning of the mixing head
Unit does not produce.
Cured material in
old mixing canula.
Unit does not produce.
The components
A and B have
been interchan-
ged; the silicone
has cured in the
system of the unit.
Exchange of the miniature fuses
20
Aid
Clean the mixing head carefully by
means of the enclosed cleaning spirals.
Attention: Use a different spiral for
each drilling, as otherwise the two
components would mix and cure.
Assemble new mixing canula.
The unit has to be dismounted
completely and cleaned by an expert.
Problem
Cause
Aid
Unit does not produce.
The filling of
Unscrew mixing head flange (no. 27)
the silicone
with a 4 mm hexagon spanner, take out
containers has
mixing head (no. 3) to the front. Loosen
fallen below the
the union nuts (no. 8a), spanner of
minimum filling;
10 mm, from the hoses and tear off
the system has
hoses. Refill silicone material and wait
sucked air.
for approx. 20 minutes until the silicone
has flown into the pipe. Put reception
bowl under the opening of the hoses,
switch unit on and press button until
both components have come out of the
hoses free of air bubbles. Reassemble
unit in reversed succession.
Unit does not
Miniature fuse is
Examine miniature fuse and exchange,
produce; lamp of
defect.
if necessary.
the operating button
does not light up.
Unit does not
The silicone
Use material recommended by the
produce in a
components do
manufacturer (a deviation of about 5 %
mixing ratio of 1:1.
not have the
can be tolerated).
same viscosity.
Unit does not
The tooth wheels
The unit has to be overhauled
produce in a
in the pump are
by an expert.
mixing ratio of 1:1.
worn unequally.
Ventilation of the production system
21