Care And Maintenance; General Notes - Dreve Dosper M/5 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Dosper M/5
Remove the lock caps from the
coupling plugs (no. 19). Press the
quick-coupling/bottle adapter of the
silicone containers onto the coupling
plugs of the unit and let them snap
hearably.
Attention! The components A and B
have to be connected according to the
printing on the unit and the applied
colour marking. Cut an opening of
approx. 0,5 cm
2
into the bottoms of
the cubitainers in order to let air come
in when producing. Remove protection
cap from mixing head (no. 4) and do
not reuse. Turn on the unit at the
operation button. Put a reception
bowl under the mixing head and
press push-button (no. 2). Keep the
push-button pressed until the test
silicone has been produced completely
18
and both components come out
homogeneously at the mixing head.
Fix mixing canula at the mixing head
(no. 4) by means of turning it to the
right by 90°. The turning of the
mixing canula can be eased by
means of the enclosed star-turn
handle (Item-no. 1565E).
The Dosper M/5 is now ready to ope-
rate. Put duplication flask under the
opening of the mixing canula and
press push-button (no. 2). As long as
the material is not cured in the mixing
canula (approx. 4 minutes) several
flasks can be filled in succession.
After having finished the filling
process do not remove the mixing
canula. Do only remove the mixing
canula before the next duplication
by means of a 90° turn to the right.
Change of bottles/cubitainers
Remove the quick-coupling/bottle
adapter from the unit by means of
tearing upwards the lock-up. Screw
quick-coupling/bottle adapter onto
the new bottles/cubitainers and
connect as described above. Observe
the correct coordination of the com-
ponents according to the colour.
Observe the contents of the contai-
ners at any time! They must not be
emptied completely, as otherwise air
gets into the system and the unit has
to be bleeded under great effort.
A minimal filling of 2-3 cm has to
Attention: Never produce against a
remain in the containers.
mixing canula with cured material!

Care and maintenance

Disconnect the unit from mains
Wipe away silicone remainders from
supply before care and maintenance!
the unit. Keep coupling plug and
Cleaning is effected with a mild
mixing head clean. The cleaning
cleaning liquid.
liquid must not get into the unit.

General notes

Repairs on the Dosper M/5 may only
- the unit is operated in accordance
be executed by experts. Disconnect
with these working instructions.
the unit from mains supply at any rate.
- extensions, new adjustments, changes
Dreve company is only responsible for
or repairs are executed by persons
the safety, reliability and performance
authorised by the company.
of the unit, if
As we are currently developing our
- the unit is exclusively used for the
products, we reserve the right for
corresponding field of application.
technical changes.
- operation is only carried out by
accordingly trained personnel.
19