Atlantic R4GHbis-i2g Notice D'utilisation Et D'installation page 49

Maradja pi connecté
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problems
The heating pictogram is
displayed on the screen
when the radiator is in
ECO mode.
The device does
not follow internal
programming commands.
The device does not follow
external
programming
commands.
The
surface
deviceis very hot.
A connected device does
not communicate with
other connected devices.
The Expert Menu is not
accessible.
The radiator does not
respond to the orders of
the pilot wire.
46
Check
The operation is normal. The radiator can warm up so
as to maintain an ECO temperature.
Check the set date and time. Make sure the device is
in PROG MODE and internal programming is selected.
Make sure the programming unit is used properly (see
the operating instructions of the Control Unit). Make
sure the device is in PROG MODE and the external
control is selected.
It is normal for the device to be hot when in use. The
maximum surface temperature is limited according to
the NF Electricity Performance Standard. However, if
of
the
you feel that your device is still too hot, make sure the
power is adapted to the size of your room by contacting
your installer and that the device is not placed near an
air stream which would affect its control mechanism.
Make sure the device is properly connected (see
"CONNECTIONS"
Connecting Devices Together procedure and start over.
The maximum number of devices that can be connected
together is 10.The maximum range is 100m open space
2
/ 20m
You saved a PIN. You must enter your PIN to
access the Expert Menu (see Expert menu section).
In this cas, to check the correct transmission of the
y
programming orders, proceed with the following check
Ordres reçus
0 volt
230 V 3 s/5 min
230V 7 s/5 min
230 V
– 115 V négatif
+ 115 V positif
Frost free and load shedding orders take priority
y
when programming is done through pilot wire or power
line. te time to change over form Comfort mode to Eco
is of the order of 12 seconds.
section).
concrete slabs.
Oscilloscope Réf/
Neutre
Cancel
the
whole
Mode obtenu
CONFORT
CONFORT – 1° C
CONFORT – 2° C
ECO
HORS GEL
ARRET CHAUFFAGE

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

R4gvbis-i2gR4gbbis-i2g

Table des Matières