6.2 Setting the DMX start address

For controlling the light effect unit with a light con-
troller, it is necessary to set the DMX start address
for the first DMX channel. If e. g. address 17 on the
controller is provided for controlling the operating
mode, set the start address 17 on the LED-
640RGBW.
Then the other functions of the LED-640RGBW
are automatically assigned to the 3 following chan-
nels (in this example 18 – 20). The next possible
start address for the following DMX-controlled unit
would be address 21 in this example.
1) Set the DMX start address:
a) Press the button MENU (8) once so that the
display (5) shows
b) Press the button ENTER. The address
adjusted starts flashing on the display.
c) Press the button
To memorize, press the button ENTER.
2) To exit the setting mode, keep the button MENU
pressed until the LED DMX (3) or MASTER (4)
lights up or wait for one minute.
3) Once the control signals of the DMX controller
are received, the red LED DMX (3) lights up and
the display shows the start address. Now the
LED-640RGBW can be operated with the DMX
controller.

7 Additional Functions

7.1 Test program

To test the unit, a short test program is available. To
start it:
1) Press the button MENU (8) repeatedly until the
display (5) shows
2) Press the button ENTER. The display flashes
and the test run starts. All LEDs and all LEDs
respectively of one colour light up alternately.
3) To cancel the test program, press the button
ENTER again.
4) To return to the previous operating mode, keep
the button MENU pressed for one second or wait
for one minute.
.
or
to set the address.
.

7.2 Indication of operating hours

and firmware version

1) Press the button MENU (8) repeatedly until the
display (5) shows the corresponding menu item:
to indicate the operating hours (Fixture
hours)
to indicate the firmware version (operat-
ing system of the unit)
2) Confirm the selection with the button ENTER.
The display shows the desired information.
3) To return to the previous operating mode, keep
the button MENU pressed for one second or wait
for one minute.

8 Cleaning the Unit

Clean the lenses at regular intervals, depending on
impurities caused by dust, smoke or other dirt par-
ticles. Only this will ensure that light is emitted at
maximum brightness. For cleaning, disconnect
the mains plug from the socket. Only use a soft,
clean cloth and a glass cleaner. Then carefully wipe
the parts dry.
To clean the other parts of the housing, only use
a soft, clean cloth. Never use any liquid; it may leak
into the unit and cause damage.

9 Specifications

Power supply: . . . . . . 230 V~/50 Hz
Power consumption: . 20 VA
Light source: . . . . . . . 320 LEDs
Ambient temperature: 0 – 40 °C
Dimensions
(W × H × D): . . . . . . . . 43 × 43 × 29 cm
Weight: . . . . . . . . . . . . 6.8 kg
(80 each in red, green,
blue and white)