En Instructions For Use / Assembly Instructions - Hansgrohe M5115-H220 73852000 Mode D'emploi

Masquer les pouces Voir aussi pour M5115-H220 73852000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
• During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Low flow with Select valve after valve replacement
Water escaping in area of swivel spout
Water escaping at the threaded base
Hot water temperature too low
Select button stiff
4
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- Improper Select valve installed
- O-ring defective
- connection hoses not completely screwed into basic
body
- O-ring at the connection hose defective.
- Hot water limiter incorrectly set
- Select button soiled
Assembly see page 31
Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot water limiter in combination
with a continuous flow water heater is not recommended.
Operation (see page 35)
• Hansgrohe recommends not to use as drinking water the first half
liter of water drawn in the morning or after a prolonged period of
non-use.
• Minor leaking may occur briefly at the spout when opening the
fitting via the lever.
• Use the lever to open the tap and set the desired temperature. The
water flow can be paused by pressing the Select button on the face
side of the spout. When the tap is not used for a longer period of
time, f.e. when retiring at night or leaving the house, it must be closed
completely by means of the lever.
Cleaning (see page 36 and enclosed brochure)
Maintenance (see page 36)
The check valves must be checked regularly according to DIN EN
1717 in accordance with national or regional regulations (at least once
a year).
Dimensions (see page 37)
Flow diagram (see page 37)
Spare parts (see page 38)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Special accessories (order as an extra)
F12 extension #43333000 (see page 34 / 38)
Remedy
- Exchange cartridge
- Exchange cartridge
- Replace Select valve #98463000 (see page 38)
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter
- Clean Select button and grease 14x1,5 O-ring (see
page 38)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M5115-h220 st 73852800

Table des Matières