Cleaning the Air
Filter
The air filter should be cleaned after
approximately 500 hours use. Remove the
air filter cover then remove the dust with a
cloth lightly dampened with mild detergent
solution.
The time needed to clean the air filter will
vary depending on the environment or how
the projector is used.
1
Turn the power off and unplug the AC
power cord.
2
Place a protective sheet (cloth) beneath
the projector and turn the projector over.
3
Remove the air filter cover.
4
Remove the filter inside, and then wipe
its dust with mild detergent.
5
Return the filter to the air filter cover.
6
Return the air filter cover.
Notes
• If the dust cannot be removed from the air
filter, replace the air filter with a new one.
• For details on new air filter, consult with
qualified Sony personnel.
• Be sure to attach the air filter cover firmly; it
may cause a problem if the air filter cover is
not installed properly.