GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations. The appliance
has been designed for use in the ducting version (air exhaust
to the outside – Fig.1B), filtering version (air circulation on the
inside – Fig.1A) or with external motor (Fig.1C).
SAFETY PRECAUTION
1. Take care when the cooker hood is operating simultaneously
with an open fireplace or burner that depend on the air in the
environment and are supplied by other than electrical energy,
as the cooker hood removes the air from the environment
which a burner or fireplace need for combustion. The negative
pressure in the environment must not exceed 4Pa (4x10-5 bar).
Provide adequate ventilation in the environment for a safe
operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
Before connecting the model to the electricity network:
- Control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualified
electrician.
- If the power supply cable is damaged, it must be replaced with
another cable or a special assembly, which may be obtained
direct from the manufacturer or from the Technical Assistance
Centre.
- This device must be connected to the mains supply through
either a plug fused 3A or hardwired to a 2 phase spur protected
by 3A fuse.
2. Warning!
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating.
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood.
D) Avoid free flame, as it is damaging for the filters and a
fire hazard.
E) Constantly check food frying to avoid that the over-
heated oil may become a fire hazard.
F) Disconnect the electrical plug prior to any mainte-
nance.
G) This appliance is not intended for use by young children
or infirm persons without supervision.
H) Young children should be supervised to ensure they do
not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels.
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions.
This appliance conforms to the European Directive EC/2002/96,
Waste Electrical and Electronic Equipment (WEEE). By making
sure that this appliance is disposed of in a suitable manner, the
user is helping to prevent potential damage to the environ-
ment or to public health.
GB
The
symbol on the product or on the accompanying pa-
perwork indicates that the appliance should not be treated as
domestic waste, but should be delivered to a suitable electric
and electronic appliance recycling collection point. Follow lo-
cal guidelines when disposing of waste. For more information
on the treatment, re-use and recycling of this product, please
contact your local authority, domestic waste collection service
or the shop where the appliance was purchased.
INSTALLATION INSTRUCTIONS
• Assembly and electrical connections must be carried out
by specialised personnel.
• Wear protective gloves before proceeding with the instal-
lation.
• Electric Connection:
- The appliance has been manufactured as a class II, therefore
no earth cable is necessary. The plug must be easily acces-
sible after the installation of the appliance. If the appliance
is equipped with power cord without plug, a suitably di-
mensioned omnipolar switch with 3 mm minimum opening
between contacts must be fitted between the appliance and
the electricity supply in compliance with the load and current
regulations.
- The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral.
• The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm. If a connection tube
composed of two parts is used, the upper part must be placed
outside the lower part. Do not connect the cooker hood
exhaust to the same conductor used to circulate hot air or for
evacuating fumes from other appliances generated by other
than an electrical source. Before proceeding with the assembly
operations, remove the anti-grease filter(s) (Fig.5) so that the
unit is easier to handle.
- In the case of assembly of the appliance in the suction version
prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which has the
same diameter as the air exhaust outlet hole. If a pipe with a
smaller diameter is used, the efficiency of the product may be
reduced and its operation may become noisier.
• Fixing to the wall:
Drill the holes A respecting the distances indicated (Fig.2).
Fix the appliance to the wall and align it in horizontal posi-
tion to the wall units. When the appliance has been adjusted,
definitely fix the hood using the screws A (Fig.4). For the
various installations use screws and screw anchors suited to
the type of wall (e.g. reinforced concrete, plasterboard, etc.). If
the screws and screw anchors are provided with the product,
check that they are suitable for the type of wall on which the
hood is to be fixed.
• Fixing the decorative telescopic flue:
Arrange the electrical power supply within the dimensions of
the decorative flue. If your appliance is to be installed in the
ducting version or in the version with external motor, prepare
the air exhaust opening. Adjust the width of the support
bracket of the upper flue (Fig.3). Then fix it to the ceiling using
the screws A (Fig.3) in such a way that it is in line with your hood
- 11 -

Publicité

loading