Télécharger Imprimer la page

herrmann MDP Instructions De Montage Et De Service page 7

Publicité

Les langues disponibles

Les langues disponibles

tEcHnical data
discharge at 15 Hz
discharge at 46 Hz
Frequency range stroke frequency
Maximum discharge pressure
dispersion of volume flow from pump to pump
negative pressure due to suction (minimal value)
Max. suction height
required filter fineness, maximum pore width
Fixation
Mounting position
weight
Maximum requirement of electric energy at maximum discharge pressure
Supply voltage
type of protection
Electronic diagnosis
ambient temperature during operation
Fuel temperature
Viscosity range of fuel
pionEEring
By implementing a large modulation range in connection with very small injection amounts in the lower load
point the Mdp enables innovative burner solutions for modern condensing boilers.
the new concept of the motor-pump combination with integrated drive electronics improves the comfort during
installation, operation and maintenance.
EconoMical
the exact dosing of the fuel enables the reliable operation of the burner with little air surplus, which increases the
efficiency of the heating system.
during full load operation the pump requires less than 60 w of electrical energy thanks to its energy-saving
magnetic drive and the low circulation rate of the fuel at low pressure.
rEliaBlE
the automatic ventilation of the fuel ensures consistent fuel injection without interruptions. this is a definite
advantage when using the Mdp in a Blue flame burner, particularly for small firing capacities.
nozzle tolerances and depositions are automatically compensated by moving the dosing function into the pump.
roBUSt
the pump functions thanks to its design virtually wear-free and thus enables a long lifespan.
due to the permanent automatic ventilation the pump is very robust against air incorporation in inadequately
installed oil systems. therefore, it can be connected to existing oil supply systems without hesitation. Even the dry
suction of fuel is permitted and cannot damage the pump.
QUiEt
Elastomer elements buffer the movement of the pistons before they reach their end positions. this causes less
noise than in an impact without braking. the casing which is isolated from vibration reduces the noise even
further.
EaSily coMBinaBlE
the pump can be used in the burner with pressure atomizing systems common on the market.
the electronic specification of the discharge and the output of the feedback signal after every correctly executed
delivery stroke facilitate the incorporation of the pump in fuel/air control systems.
MdP 20
650 g/h
1950 g/h
15-50 Hz (51 Hz)*
50 bar
+/- 4 %
-0,3 bar
3 m
40 μm
3x Ø 6.1 (for screw connection M6)
Vertical suction connection pointing upwards
2,3 kg
60 w
230 V ac
ip 20
Monitoring for excessive discharge
5 - 60°c
5 - 40°c
2 - 12 mm²/s
MdP 30
Fuels
1000 g/h
Heating oil El pursuant to din 51603-1
3000 g/h
low-sulphur heating oil El pursuant to din 51603-1
Heating oil El a Bio 10 pursuant to din SpEc 51603-6, low-sulphur
heating oil El with up to 10 % FaME part according to the quality
requirements of din 14214
tests
according to din En 620335: Security of electrical devices for
domestic use and similar purposes (also includes: EMc directive,
Machinery directive, low Voltage directive
pursuant to din En iSo 23553-1: Safety and control facilities for oil
burners and oil burning devices - Specific requirements - part 1:
Stop valves for oil burners
* activating start booster function for the pump by application of
a frequency signal of 51 Hz + 2 Hz. the brief increase in conveying
capacity at start-up with low levels of injection pressure creates a steep
pressure flank.
tHE adVantagES

Publicité

loading