Ice Maker Dispenser:
The machine is heavy, so the use of a mechanical lift is
recommended for lifting the machine high enough to install
on top of the stand or counter top. If placing on a machine
stand, align it with the back. Secure it to the stand with the
hardware provided with the stand. If placing on a counter
top, no additional fastening is required. Sealing the edges of
the dispenser to the cabinet is recommened to make cleaning
easier.

PLUMBING:

PLUMBING CONNECTIONS MUST
CONFORM TO ALL APPLICABLE CODES
Water Inlet
Air Cooled Models: The recommended water supply is
potable cold water. Use 3/8" O.D. copper tubing, connect to
the 3/8" male flare at the back of the cabinet. Install a hand
valve near the machine to control the water supply.
Water Cooled Models: A separate 3/8" O.D. copper line is
recommended, with a separate hand valve to control it. It is
connected to a 3/8" FPT condenser inlet at the back of the
cabinet.
Drains
Air Cooled Models: There is one 3/4" FPT drain at the back
of the cabinet, the drain line is of the gravity type, and a 3
cm per meter fall is an acceptable pitch for the drain tubing.
There should be a vent at the highest point of the drain line,
and the ideal drain receptacle would be a trapped and vented
floor drain. Use only 3/4" rigid tubing.
Water Cooled Models: In addition to the above mentioned
drain, a separate condenser drain must be installed. Connect
it to the 1/2" condenser drain connection at the back of the
cabinet.

ELECTRICAL:

ELECTRICAL CONNECTIONS MUST
CONFORM TO ALL APPLICABLE CODES
The electrical power to the unit is supplied through the
junction box at the rear of the machine.
Check the nameplate (located on the back panel) for the
voltage requirements, and for the minimum circuit ampacity.
The machine requires a solid chassis to earth ground wire.
The ice maker should be connected to its own electrical
circuit so it would be individually fused. Voltage variation
must remain within design limitations, even under starting
conditions.
The electrical disconnect switch with fuse protection must
be a two pole type with a minimum of 3 mm between open
contacts.

FINAL CHECK LIST

1. Is the ice system installed indoors in a location where the
air and water temperatures are controlled, and where they do
not exceed the design limitations?
2. Is there an electrical service disconnect within sight of
the installed machine? Has the voltage been checked, and
compared to nameplate requirements?
3. Have all the plumbing connections been made and
checked for leaks?
4. Has the machine and bin been leveled?
5. Is there a minimum of 150 mm clearance at the sides of
the machine for proper service access and air circulation?
6. Is the water pressure a minimum of 1 bar?
7. Has the machine been secured to the machine stand (if a
stand is used)?
8. Is there clearance over the top of the machine for service
access?
9. Is there a water shut off valve installed near the machine?

INITIAL START UP

Pre-Start Inspection
1. Remove the two front panels.
2. Inspect the interior of the machine for loose screws or
wires. Check that no refrigerant lines are rubbing each
other. Check that the fan blade turns freely (air cooled).
3. Remove any and all packaging material including any that
may be inside the ice storage bin.
4. Check that the inner bin bottom is properly seated at the
bottom of the ice storage bin.
5. Check that the unit is installed correctly according to the
final check list.