1. Set the Rotary Dial to
position.
2. Connect the red test lead
to the VΩ terminal and the
black test lead to the COM
terminal.
3. Connect the test leads to
the circuit under test. The
reading is displayed.
AC
Cat. No. 2237-20 only:
Pressing the Hz Key toggles
the reading between AC
Voltage and Hz. NOTE: Hz
Function requires 40V or more.
CAUTION
Readings of frequency may fl uctuate or be
infl uenced in noisy environments.
DC Voltage
DANGER
To avoid electrical shock:
Never make measurement on a circuit in
which voltage over DC600V exists.
Do not use with the Battery Cover removed.
Keep fi ngers away from jaws during mea-
surements.
1. Set the Rotary Dial to
position.
2. Connect the red
test lead to the VΩ
terminal and the
black test lead to
the COM termi-
nal.
3. Connect the red
test lead to the
positive (+) side
a n d b l a c k t e s t
leads to the nega-
tive (-) side of the
circuit under test.
The reading is displayed. A reversed connection
is indicated as a negative value.
Resistance/Continuity/Capacitance
Measurements
DANGER
To reduce the risk of electric shock for
Resistance, Continuity, and Capacitance
measurements, never use the meter on an
energized circuit. Make sure a capacitor is
fully discharged before touching or attempt-
ing to make a measurement.
Do not use with the Battery Cover removed.
Resistance
1. Set the Rotary Dial to
position.
2. Connect the red test
lead to the VΩ ter-
minal and the black
test lead to the COM
terminal.
Confi rm "OL" is indi-
cated on the display,
and then short-circuit
the tips of test leads
to make the indica-
tion zero.
3. Connect the test leads to the both ends of the
resistor under test.
4. The reading is displayed.
CAUTION
After shorting the test leads, the displayed
value may not be zero due to the resistance
of test leads themselves.
Continuity
1. Set the Rotary Dial to
position.
2. Connect the red test lead
to the VΩ terminal and the
black test lead to the COM
terminal.
Confi rm "OL" is indicated on
the display, and then short-
circuit the tips of test leads
to make the indication zero.
A buzzer will sound.
3. Connect the test leads to
the both ends of the conductor under test. If the
resistance under test is 30 Ω or less, the buzzer
will sound.
6
Capacitance
1. Set the Rotary Dial to
position.
2. Connect the red test lead to the VΩ terminal and
the black test lead to the COM terminal.
3. Discharge capacitor.
4. Connect the test leads to the both ends of the
capacitor under test.
5. The reading is displayed.
DC Current (Cat. No. 2236-20 only)
DANGER
To avoid electrical shock:
Never make measurement on a circuit in
which voltage over AC600V exists.
Do not use with the Battery Cover removed.
1. Set the Rotary Dial to
position. DC mark
is displayed.
2. Connect the red test
lead to the VΩ ter-
minal and the black
Flame
sensor
test lead to the COM
probe
terminal. Contact the
Control
red test lead to the
Module
fl ame sensor probe
and the black test
lead to the control
module.
3. Turn on the heating unit. The reading is dis-
played.
Temperature (Cat. No. 2236-20 only)
WARNING
Never connect the Temperature Probe to an
energized circuit.
1. Set the Rotary Dial to
position.
2. Connect the K-type Tem-
perature Probe to the input
terminal. The positive (+)
side of Probe should be
connected to VΩ.
3. Place the probe sensor in
the desired location.
4. The reading is displayed.
CAUTION
When the Rotary Dial is set to
, the room
temperature should be displayed. If anything
else is displayed, something may be wrong
with the meter. Stop using the meter imme-
diately.
Worklight LED ON/OFF
To turn the light on and off, press the
HOLD Key
Data Hold Function - Freezes the value on the
display. Press the "HOLD" button to freeze the
reading. The reading will be held regardless of
subsequent variation in input. HOLD is displayed
with the reading. To exit Data Hold mode, press the
HOLD button again.
CAUTION
The Data Hold readings are released when the
meter enters Sleep Mode.
Sleep Mode
The clamp meter is automatically powered off in
about 20 min after the last Rotary Dial or button
operation. To reset, rotate the Rotary Dial to OFF.
If the display is still blank when a new Rotary Dial
setting is selected, replace the batteries.
The sleep mode is disabled when the MIN/MAX
function is selected.
The clamp meter does use battery power in sleep
mode. Be sure to switch the tool to OFF to conserve
battery power.
7