Neutralisation box up to 40 kW
6
Installation of the condensate pump, art. no. 20 71 267 in the neutralisation box
Place the condensate pump, art. no. 20 71 267 with pre-mounted condensate pressure hose
into the receptacle provided for it in the neutralisation box as shown. Place the mains and alarm
cables as well as the condensate pressure hose in the two corners as shown.
Warning
Ensure when doing this that the pump is installed in a horizontal position!
Only when using the condensate pump, art. no. 20 71 267: remove the two corners of the lid
using a suitable tool (side cutter, knife, or similar). Place the lid on the neutralisation box until it
engages.