Specifications - Schumacher Electric PID-410 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROBLEM
Inverter does not turn on.
10.

SPECIFICATIONS

Model: PID-410 / PIF-410
Maximum Continuous Power
Surge Capability (Peak Power)
No Load Current Draw
Wave Form
Input Voltage Range
Output Voltage Range
Low Battery Alarm
Low Battery Shutdown
High Battery Shutdown
Optimum Efficiency
AC Outlet
DC Output
Dimensions
Weight
REASON
Poor contact at terminals
Fuse is blown.
Inverter may be defective.
Audible, 11V ± 0.3V DC
Two, NEMA 5 - 15 USA
One, USB 5V 0.5 Amp
• 15 •
SOLUTION
Check for poor connection
to battery or power supply.
Make sure connection points
are clean. Rock clamps
back and forth for a better
connection.
A blown fuse is usually
caused by reverse polarity
or a short circuit within the
inverter.
To replace, contact a qualified
service technician who will
diagnose the inverter and
replace the fuse(s) with the
appropriate replacement(s).
See warranty and call
Customer Service 1-800-621-
5485 (Hours 7:00 am to 5:00
pm CST).
410 Watts
820 Watts
<0.4A
Modified Sine Wave
10.5V – 15.5V DC
120V ± 5% AC
10.5V ± 0.3V DC
15.0V ± 0.5V DC
85%
5" L x 4" W x 2.2" H
approximately 2 lbs.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pif-410Pid-760Pif-760

Table des Matières