TROUBLESHOOTING

PROBLEM
The Instant Power™ won't
jump start my car.
The Instant Power™ won't
power my 12V device.
The battery in the Instant
Power™ won't hold a
charge.
8.

SPECIFICATIONS

Internal battery Type
Nominal Voltage
Capacity
DC Power Outlet (Max. Continuous Load)
Dimensions (H x W x D)
weight
POSSIBLE CAUSE
Clips are not making a
good connection to the
battery.
Connections are reversed.
The Instant Power™ bat-
tery is not charged.
The vehicle's battery is
defective.
The 12V device is not
turned on.
The Instant Power™ bat-
tery is not charged.
The 12V device draws
more than 15A or has a
short circuit
The battery is bad (will not
accept a charge).
9
REASON/SOLUTION
Check for poor connection
to battery and frame. Make
sure connection points are
clean. Rock clips back and
forth for a better connection.
Disconnect the Instant
Power™ and reverse the
clips.
Check the battery charge
status by pressing the
button on the front of the
Instant Power™. See LED
Indicators section of this
manual.
have the battery checked.
Turn on the 12V device.
Check the battery charge
status by pressing the
button on the front of the
Instant Power™. See LED
Indicators section of this
manual.
Disconnect the 12V device.
The internal breaker will
automatically reset after a
minute or two. Try the 12V
device again. If it happens
again, replace the 12V
device.
have the battery checked.
Maintenance-free AgM Lead-Acid
12V DC
18 Ah
15A
29.21 x 24.13 x 19,66 cm
8.5 kg.

Publicité

Table des Matières
loading

Table des Matières