Operating the Reader
4
Card Reading – The reader can read both HID Prox
EM 410x (ASK) cards.
When a HID Prox
output the ID data in Wiegand according to the bit
format of the card up to 85-bits.
When an EM card is read, the reader will output the
ID data either in Wiegand or Clock & Data format as
per the selected EM Mode. Wiegand EM ID data is
always sent as 26-bits. Clock & Data EM ID data is
always sent as 40-Bits.
EM Mode Line – For EM Cards the EM Mode Line selects if the
EM ID data is sent in Wiegand or Clock & Data format. When
the Mode Line is open, the EM ID data is sent as Wiegand.
When the Mode Line is pulled to GND, the EM ID data is sent
as Clock & Data format.
Hold Line – The hold line is active low. When active and a card
is read, no card data is sent on the Wiegand lines; however,
the reader will continue to buffer the last card ID read and will
send that ID data when the hold line is released.
Keypad Entry – The reader supports nine keypad formats for
use with various controllers. The default keypad format is
Single Key, Wiegand 4-Bit. For Honeywell panels, a
termination key (#) must be pressed after the PIN is entered
so that the panel knows the PIN code has been fully entered.
Keypad Programming Mode – The keypad on the readers is
pre-programmed with default settings for standard use.
Changing the settings is done via the keypad driven
programming menu.
Men
Setting
u
1
Selecting Keypad Transmission Format
Option # Keypad Transmission Format
Single Key, Wiegand 6-Bit (Rosslare
1
Format)
Single Key, Wiegand 6-Bit with
2
Nibble + Parity Bits
Single Key, Wiegand 8-Bit, Nibbles
3
Complemented
4 Keys Binary + Facility code,
4
Wiegand 26-Bit
1 to 5 Keys + Facility code,
5
Wiegand 26-Bit
6 Keys Binary-Coded Decimal
6
(BCD) and Parity Bits, Wiegand 26-
Bit
7
Reserved
8
1 to 8 Keys BCD, Clock & Data
9
Single key, Wiegand 4-Bit
Changing the Programming code
2
3
Changing the Facility code
4
Selecting the Keypad Backlight Setting
Option # Keypad Backlight Setting
1
Always off
2
Always on
10 sec. backlight after key press
3
otherwise off
10 sec. backlight after key press
4
otherwise dimmed
0
Return to Factory Default Settings
9
(FSK) and
TM
TM
card is read, the reader will
Default
To enter programming mode press "#" four times and enter
the programming code. The default programming code is
1234. While you are in programming mode you can exit at
anytime by pressing "#".
Keypad transmission format
To select a keypad transmission format, enter
programming mode, press "1", then enter the
Option # for the Keypad Transmission format you
wish to select.
Note: For Option 8 an additional entry is required,
for further details please refer to the format guide.
Changing the programming code
To change the programming code, enter
programming mode, press "2", then enter the new
four digit programming code.
Note: For new reader installations it is advisable for
security reasons to change the programming code
upon installation of the reader.
Changing the facility code
This facility code is only used in Keypad
Transmission formats 4 and 5. To change the facility
code, enter programming mode, press "3", then
enter the new three digit facility code. The facility
code must be between 000 and 255.
Selecting the keypad backlight setting
To change the keypad backlight setting, enter
programming mode, press "4", then enter the
Option # for the keypad backlight setting you wish
to select.
Return to Default Settings
To return to default settings, enter programming
mode, press "0", then enter the programming code.
Replacing a Lost Programming Code
In the event that the Programming code is forgotten:
1.
Remove power from the reader.
2.
Activate the tamper by removing the reader from
the wall or removing the reader's case.
3.
Apply power to the reader and within the next 10
seconds you can enter programming mode using the
factory default Programming code 1234.
4.
You can now change the programming code or
return the reader to its default settings.
*
1234
0
*
OmniProx Rev. S
800-20879 Rev. A