4.2 Interference in the pipe system
Components integrated in the pipes, bends, valves, reductions, etc� lead to turbu-
lence of the medium� This affects the function of the unit�
Recommendation: Adhere to the distances between sensor and sources of inter-
ference:
S
D = pipe diameter; S = sources of interference
4.3 Installation procedure
► Ensure that the system is free of pressure during installation�
► Ensure that no media can leak at the mounting location during installa-
tion�
► Grease the threads of the process connection (1), adapter (2) and nut (3)�
Note: No grease must be applied to the sensor tip (A)�
► Screw suitable adapter into the process connection�
► Place the flow monitor onto the adapter and tighten the nut� Tightening torque
25 Nm� Ensure that the unit is correctly oriented�
5...10 x D
Flow
Low
High
0 1 2 3 4 5 6 7 8 9
Setpoint
1
2
A
3...5 x D
S
Flow
Low
High
0 1 2 3 4 5 6 7 8 9
Setpoint
3