Unpacking; Correct Use - IKA RW 47 D Mode D'emploi

Masquer les pouces Voir aussi pour RW 47 D:
Table des Matières

Publicité

• Never cover the ventilation slots or cooling fi ns
on the motor as these are needed for cooling
the drive system.
• Imbalance of the output shaft, the chuck and
in particular the stirring tools can lead to un-
controlled resonant vibrational behaviour of
the equipment and the whole assembly. Glass
apparatus and stirrer containers can be dama-
ged or shattered by this. it can caution injury to
the operator, as can the rotating stirring tool.
In this case exchange the stirring tool for one
without imbalance or remedy the caution of the
imbalance. If there still is imbalance, return it
to the dealer or the manufacturer along with a
description of the fault.
• Beware of the risk of
- flammable materials
- glass breakage as a result of mechanical
ATTENTION!
shaking power.
• There may be electrostatic activity between the
medium and the output shaft which could pose
a direct danger.
ATTENTION!
• Process pathogenic materials only in closed
vessels under a suitable extractor hood. Please
contact IKA
• Do not operate the appliance in explosive at-
mospheres, with hazardous substances or un-
der water.

• Unpacking

- Please unpack the device carefully
- In the case of any damage a detailed report
must be set immediately (post, rail or for-
warder)
• Use
The laboratory stirrer IKA
used to stir and mix liquids of low to medium
viscosity with various stirring tools.
if you have any questions.
®
RW 47 D can be
®
• Only process media that will not react danger-
ously to the extra energy produced through-
processing. This also applies to any extra ener-
gy produced in other ways, e.g. through light
irradiation.
• Safe operation is only guaranteed with the ac-
cessories described in the "Accessories" chapter.
• Always disconnect the plug before fi tting ac-
cessories.
• The appliance can only be disconnected from
the mains supply by pulling out the mains plug
or the connector plug.
• The socket for the mains cord must be easily
accessible.
• After an interruption in the power supply, or a
mechanical interruption during a stirring pro-
cess, the unit does not automatically restart.
For protection of the equipment
• The appliance may only be opened by experts.
• The voltage stated on the type plate must cor-
respond to the mains voltage.
• Socket must be earthed (protective ground
contact).
• Protect the appliance and accessories from
bumps and impacts.
Unpacking
• Delivery scope
Stirring unit IKA
- IKA
RW 47 D stirring unit as per order,
®
- Chuck key,
- Allen key,
- 4 Allen screws
- Operating instructions

Correct use

Operating modes: on stand
®
RW 47 D
13

Publicité

Table des Matières
loading