3 Set-up and installation
2 Press the lateral holding burls upwards with your fingers (2.),
stem from above with the thumbs.
3 Remove the front screen to the front (3.).
  3‒5 Remove the front screen
3.4.2

Remove the protective cover

1 Unhook the protective cover from the rearward facing holding
burls (1.), lift at the back (2.) and remove to the front (3.).
  3‒6 Remove the protective cover
Installation and operating manual
14
  3‒7 Without protective cover
3.4.3
Moving the switch box to the service
position
To facilitate work on the hydraulics of the indoor unit, the switch box
can be moved to the service position.
1 Loosen the screws (a) of the holder of the switch box.
  3‒8 Moving the switch box to the service position
2 Remove the switch box from the front and insert it into the
bracket with the hooks on the rear brackets.
  3‒9 Switch box in the service position
3.4.4

Open the switch box

To make the electrical connections, the switch box itself must be
opened. This can be done in both the normal and the service
position.
1 Loosen the front screw.
2 Push the cover upwards and pull it away to the front.