3
Set-up and installation
3.4
Preparing the device for
installation
3.4.1

Remove the front screen

1
Undo the screws (1.).
2
Press the lateral holding burls upwards with your fingers (2.),
stem from above with the thumbs.
3
Remove the front screen to the front (3.).
Fig. 3-7
Remove the front screen
Installer reference guide
14
3.4.2

Remove the protective cover

1
Unhook the protective cover from the rearward facing holding
burls (1.), lift at the back (2.) and remove to the front (3.).
Fig. 3-8
Remove the protective cover
Fig. 3-9
Without protective cover
3.4.3
Moving the controller housing to the
service position
To facilitate work on the hydraulics of the indoor unit, the control box
can be moved to the service position.
1
Loosen the screws (1) of the holder of the controller housing.
Fig. 3-10

Moving the controller housing to the service position

Heat pump (indoor unit) with integrated heat accumulator
Daikin Altherma ETS(X/H)(B)-D
008.1447299_00 – 06/2019 – EN